Send Email
Send SMS
Search
Nrs Solutions A Co.
Nrs Solutions A Co.


Addressable Fire Alarm Panel

Our product range includes a wide range of addressable fire alarm panel intellifire, addressable fire alarm panel zicom, addressable fire alarm panel global fire, addressable sub panel, analogue addressable fire alarm panel - expandable and analogue addressable fire alarm panel - junior.

Addressable Fire Alarm Panel Intellifire

REQUEST CALLBACK

Addressable Fire Alarm Panel Intellifire
Approx. Rs 39,000 / Piece(s)
Get Best Quote

We are a noteworthy organization in the domain, engaged in providing Addressable Fire Alarm Panel Intellifire that can expand to two loops & support multiple languages, offered fire alarm panel is provided in customized options on demand. We are giving this fire alarm panel to the customers at numerous specifications in accordance with their needs.

Features:

  • Easy maintenance
  • Longer functional life
  • Multiple language support

Other Details:

  • Single loop panel - Expandable to two Loops using JNR-V4-Card
  • Supports connection to Mini-repeaters via RS422/485, Fibre Optic or TCP/IP interfaces
  • 125 Device addresses per loop
  • 32 Individually programmable sounder addresses per Loop
  • 96 VULCAN 2 (addressable) ultra low current sounders or beacons per Loop. Only 64 of these units
  • should be installed per loop when combined sounder beacons are being used. This number
  • includes addressable, shadow, auxiliary and detector-sounder/ beacon versions of these units
  • 2 Fire output relays (change-over) and 1 Fault relay (Normally closed)
  • 2 Conventional alarm outputs (Individually programmable)
  • 384 Fully programmable zones
  • 512 Fully programmable sounder groups together with 512 Input/Output groups
  • Event log (rolling, 2000 entries)
  • Compatible with GFE’s range of Analogue Addressable Devices
  • Backlit LCD display with 4 rows of 40 characters
  • PC Programming using Upload/Download GFE Connector Software
  • PC Graphics package ODYSSEY for alarm management and reporting (optional)
  • Multiple language support (menu selectable)
  • Integrated 16 zone LED fire zone indication

Technical Specifications:
Technical SpecificationsJunior V4
Primary Supply Voltage - Input230+10%-15% V AC
Primary Supply voltage - Output28.5V DC Nominal
Primary Supply current - Output2.4A @ 28.5 V DC nominal (max.)
Secondary Supply voltage21.0 Min. - 27.2 Max. V DC - Bat Charger o/p 28V DC
Secondary Supply current Output1.6 Amp Maximum @ 20°C
Internal Battery Capacity - Maximum2 X 12V 7 Ah Sealed VRLA Lead Acid Batteries
Loop Current Drive275 mA/Loop
Auxiliary Relay Outputs2 Fire (COM-NC-NO)-1 Fault (COM-NC) non-supervised
Conventional Sounder Circuits2-400 mA max. current drive per circuit-Fully monitored
Max. Humidity95% RH Non-Condensing
Operating Temperature0°C to 40°C
Weight2.0 kg - 7 kg (inc. 2 X 7 AH 12 V bat.)
Dimensions272 (w) X 404 (H) X 107 (D) mm
Order CodeDescription
JNR-V4-1Junior V4, 1 Loop Expandable to 2 Loops, PSU 2.4 A
JNR-V4-2Junior V4, 2 Loops, PSU 2.4 A
JNR-V4-CardJunior V4 Loop Card Expansion from 1 to 2 Loop


Yes! I am interested

Addressable Fire Alarm Panel Zicom

REQUEST CALLBACK

Addressable Fire Alarm Panel Zicom
Approx. Rs 49,000 / Piece(s)
Get Best Quote

Our team of diligent members works in close-coordination with clients to provide Addressable Fire Alarm Panel Zicom. The offered fire alarm panels offer a cost effective solution for small to medium sized installations. These fire alarm panels can be availed from us in various specifications as per customer’s requisites. We deliver these fire alarm panels within promised time frame.

Features:


  • 125 Device addresses per loop
  • Functional accuracy
  • Efficiency

Other Details:

  • Single loop panel - Expandable to two Loops using JNR-V4-Card
  • Supports connection to Mini-repeaters via RS422/485, Fibre Optic or TCP/IP interfaces
  • 125 Device addresses per loop
  • 32 Individually programmable sounder addresses per Loop
  • 96 VULCAN 2 (addressable) ultra low current sounders or beacons per Loop. Only 64 of these units
  • should be installed per loop when combined sounder beacons are being used. This number
  • includes addressable, shadow, auxiliary and detector-sounder/ beacon versions of these units
  • 2 Fire output relays (change-over) and 1 Fault relay (Normally closed)
  • 2 Conventional alarm outputs (Individually programmable)
  • 384 Fully programmable zones
  • 512 Fully programmable sounder groups together with 512 Input/Output groups
  • Event log (rolling, 2000 entries)
  • Compatible with GFE’s range of Analogue Addressable Devices
  • Backlit LCD display with 4 rows of 40 characters
  • PC Programming using Upload/Download GFE Connector Software
  • PC Graphics package ODYSSEY for alarm management and reporting (optional)
  • Multiple language support (menu selectable)
  • Integrated 16 zone LED fire zone indication

Technical Specifications:
Technical SpecificationsJunior V4
Primary Supply Voltage - Input230+10%-15% V AC
Primary Supply voltage - Output28.5V DC Nominal
Primary Supply current - Output2.4A @ 28.5 V DC nominal (max.)
Secondary Supply voltage21.0 Min. - 27.2 Max. V DC - Bat Charger o/p 28V DC
Secondary Supply current Output1.6 Amp Maximum @ 20°C
Internal Battery Capacity - Maximum2 X 12V 7 Ah Sealed VRLA Lead Acid Batteries
Loop Current Drive275 mA/Loop
Auxiliary Relay Outputs2 Fire (COM-NC-NO)-1 Fault (COM-NC) non-supervised
Conventional Sounder Circuits2-400 mA max. current drive per circuit-Fully monitored
Max. Humidity95% RH Non-Condensing
Operating Temperature0°C to 40°C
Weight2.0 kg - 7 kg (inc. 2 X 7 AH 12 V bat.)
Dimensions272 (w) X 404 (H) X 107 (D) mm
Order CodeDescription
JNR-V4-1Junior V4, 1 Loop Expandable to 2 Loops, PSU 2.4 A
JNR-V4-2Junior V4, 2 Loops, PSU 2.4 A
JNR-V4-CardJunior V4 Loop Card Expansion from 1 to 2 Loop
Yes! I am interested

View PDF

Addressable Fire Alarm Panel Global Fire

REQUEST CALLBACK

Addressable Fire Alarm Panel Global Fire
Approx. Rs 48,000 / Piece(s)
Get Best Quote

Owing to the efforts of our qualified professionals, we have been able to offer Addressable Fire Alarm Panel Global Fire. These fire alarm panels are designed with the help of quality material as per set industry norms. The offered fire alarm panels are tested on numerous parameters by vendor’s quality controllers in order to offer flawless range to our customers. Offered fire alarm panels are provided to customers at reasonable rates.

Features:


  • 384 Fully programmable zones
  • Easy installation & usage
  • Elevated performance

Other Details:

  • Single loop panel - Expandable to two Loops using JNR-V4-Card
  • Supports connection to Mini-repeaters via RS422/485, Fibre Optic or TCP/IP interfaces
  • 125 Device addresses per loop
  • 32 Individually programmable sounder addresses per Loop
  • 96 VULCAN 2 (addressable) ultra low current sounders or beacons per Loop. Only 64 of these units
  • should be installed per loop when combined sounder beacons are being used. This number
  • includes addressable, shadow, auxiliary and detector-sounder/ beacon versions of these units
  • 2 Fire output relays (change-over) and 1 Fault relay (Normally closed)
  • 2 Conventional alarm outputs (Individually programmable)
  • 384 Fully programmable zones
  • 512 Fully programmable sounder groups together with 512 Input/Output groups
  • Event log (rolling, 2000 entries)
  • Compatible with GFE’s range of Analogue Addressable Devices
  • Backlit LCD display with 4 rows of 40 characters
  • PC Programming using Upload/Download GFE Connector Software
  • PC Graphics package ODYSSEY for alarm management and reporting (optional)
  • Multiple language support (menu selectable)
  • Integrated 16 zone LED fire zone indication

Technical Specifications:
Technical SpecificationsJUNIOR V4
Primary Supply Voltage-input230+10%-15%V AC
Primary Supply Voltage-output28.5 VDC nominal
Primary Supply Current -output2.4 A @28.5 V DC nominal (max.)
Secondary Supply Voltage21.0 Min. -27.2 Max. V DC- BAT charger 0/p 28 V DC
Secondary Supply Current Output1.6 Amp Maximum @20 c
Internal Battery Capacity- Maximum2 x 12 v7Ah Sealed VRLA LEAD Acid Batteries
Loop Current Drive275 mA/Loop
Auxiliary Relay Outputs2.Fire (COM-NC-NO) -1 Fault (COM-NC) non- supervised
Conventional Sounder Circuits2-400 mA Max. current drive per circuit- Fully monitored.
Max. Humidity95% RH Non- Condensing
Operating Temperature0 c to 40 C
Weight2.0 kg -7kg (ice.2x7 AH 12V bat.)
Dimensions272(W) x404 (H) x107(D)mm
Order CodeDESCRIPTION
JNR-V4-1Junior v4, Loop Expandable to 2 Loops, PUS 2.4 A
JNR-V4-2junior V4, 2 Loops, PUS 2.4A
JNR-V4-CARDJunior V4 Loop Card Expansion form 1 to 2 Loop

Yes! I am interested

View PDF

Addressable Sub Panel

REQUEST CALLBACK

Addressable Sub Panel
Approx. Rs 43,000 / Piece(s)
Get Best Quote

With the assistance of our team of skilled workers, we are offering Addressable Sub Panel. The offered panel is developed with premium quality material and modern techniques. This panel is highly appreciated by our customers due to its quality range. Customers can avail this panel from us as per their requisites.

Features:


  • Fine finish
  • PC Programming using Upload
  • Light weight

Specificaitons:
Loops1, 2 or 3 loops - max. 275 mA / Loop1 to 9 loops - max. 275 mA / Loop
Sounder Ouptputs / Sub-panel2 at 28V DC / 500 mA each4 / 6 / 8 24V DC / 500 mA each
Aux. Relays Fire / sub-panel2 rated 50V AC / DC 1 A resistive2 rated 50V AC / DC 1 A resistive
Aux. Relays Fault / sub-panel1 rated 50V AC / DC 1 A resistive1 rated 50V AC / DC 1 A resistive
Aux Power Output28V DC 300 mA28V DC 300 mA
Additional OutputsN/AN/A
Primary SupplyN/A230 + 10% -15% V AC
Secondary Supply28V DC Nominal28V DC Nominal
Power Supply RatingN/A150W
Quiescent Current (No Devices)90 mA90 mA / Sub-Panel
Batteries (Internal)2 X 12V 12 AH2 X 12V 12 AH
Dimensions113 (L) X 180 (W) X 26 (H) mm375 (H) X 345 (W) X 139 (D) mm
Weight (No Batteries)0,3 Kg4, 2 Kg (no batteries)
Operating Temperature0°C to + 40°C0°C to + 40°C
Storage Temperature-10°C to + 50°C-10°C to + 50°C
Humidity / ProtectionN/AMax 95% no condensation / IP21

Other Specifications:
Order CodeJ-Net Sub-Panel BoardOrder CodeJuno Net Sub-Panel (Boxed)
J-Net-SPSub-Panel Board w/o Loop CardJ-Net-SPX-0011 Loop - 5.4A PSU
J-Net-SP-001-SASub-Panel Board w/1 LoopJ-Net-SPX-0022 Loop - 5.4A PSU
J-Net-SP-002-SASub-Panel Board w/2 LoopJ-Net-SPX-0033 Loop - 5.4A PSU
J-Net-SP-003-SASub-Panel Board w/3 LoopJ-Net-SPX-0044 Loop - 5.4A PSU
J-Net-SPX-0055 Loop - 5.4A PSU
J-Net-SPX-0066 Loop - 5.4A PSU
J-Net-SPX-0077 Loop - 5.4A PSU
J-Net-SPX-0088 Loop - 5.4A PSU
J-Net-SPX-0099 Loop - 5.4A PSU
Yes! I am interested

Analogue Addressable Fire Alarm Panel - Expandable

REQUEST CALLBACK

Analogue Addressable Fire Alarm Panel - Expandable
Approx. Rs 65,000 / Piece(s)
Get Best Quote

Juno net is a powerful Analogue Addressable Fire Alarm Panel with networking capabilities that facilitate the configuration of complex wide area fire detection systems. Modular construction and distributed intelligence allow systems of up to 96 loops to be constructed. With a high level of built-in redundancy and emergency back-up features, the juno net is fully equipped to control the most complex installations.


Features:

  • Fully expandable system from 1-96 Loops with distributed intelligence for added security
  • 125 Device addresses per loop
  • Up to 96 Loop sounders with 32 individually programmable addresses per Loop
  • 96 VULCAN 2 (addressable) ultra low current sounders or beacons per Loop
  • Only 64 of these units should be installed per loop when combined sounder beacons are being used
  • This number includes addressable, shadow, auxiliary and detector-sounder/beacon versions of these units
  • Compatible with major analogue addressable communications protocols
  • 2 Fire output changeover relays and 1 Fault output relay (NC)
  • Open collector outputs for Fire, Fault and pre-alarm remote indication
  • 2 Fully monitored conventional sounder outputs on main panel and each sub panel
  • Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
  • 384 Programmable zones
  • 512 Fully programmable sounder and I/O groups
  • Event Log 2000 entries FIFO
  • Backlit LCD display 4 row x 40 characters
  • Programming options: onboard keypad, Remote IR (optional), PS2 Keyboard and
  • GFE Connector Software
  • PC Graphics package ODYSSEY for alarm management and reporting (optional)
  • Multiple Language support (menu selectable)
  • MODBUS (ASCII & RTU) and BMS support


Specifications:

Technical Specifications1-4 LOOPS4-13 LOOPS
Loops1 to 4 loops - max 275 m A per loop4 to 13 loops - max 275 m a per loop
Sounder Outputs2 at 28 V DC/ 500 m A each4/6/8 24 V DC /500 m A each
Aux. Relays Fire2 reted 50 VAC/ DC 1 A resistive2 rated 50 VAC / DC 1 A resistive
Aux. Relay Fault1 reted 50 VAC / DC 1A resistive1 rated 50 VAC /DC 1 A resistive
Auxpower Output28 V DC 600 m A28 V DC 600 m A
Additional OutputsMultiplexed up to 384 ZonesMultiplexed up to 384 Zones
Primary Supply230 + 10 % -15 % V AC230 +10 % - 15% V AC
Secondary Supply28 V DC Nominal28 V DC Nominal
Power Supply Rating65 W (1-3 loop) -150 W (4 loop)150W (4-6 loop) -200 W (7-13 loop)
Quiescent Current (no Devices)130 m A (1-3 loop) -180 m A (4 loop)130 m A +90 m A / sub- panel
Batteries (internal)2x12 V 12 AH2 x 12 V 12 AH
Dimensions375 (H) X 345(w) X 139(D) mm420(H) X 550 (W) x 127 (D)mm
Weight5,1 kg (no batteries)8,1 kg (no batteies)
Yes! I am interested

View PDF

Analogue Addressable Fire Alarm Panel - Junior

REQUEST CALLBACK

Analogue Addressable Fire Alarm Panel - Junior
Approx. Rs 42,000 / Piece(s)
Get Best Quote

The global fire junior V4 is a single loop Analogue Addressable Fire Alarm Panel which can be expanded to two loops. It provides a cost effective solution for small to medium sized installations. The junior v4 can support up to 125 addressable devices on each loop which are compatible with major analogue addressable communications protocols.

Features:

  • Single loop panel - Expandable to two Loops using JNR-V4-Card
  • Supports connection to Mini-repeaters via RS422/485, Fibre Optic or TCP/IP interfaces
  • 125 Device addresses per loop
  • 32 Individually programmable sounder addresses per Loop
  • 96 VULCAN 2 (addressable) ultra low current sounders or beacons per Loop. Only 64 of these units
  • should be installed per loop when combined sounder beacons are being used. This number
  • includes addressable, shadow, auxiliary and detector-sounder/ beacon versions of these units
  • 2 Fire output relays (change-over) and 1 Fault relay (Normally closed)
  • 2 Conventional alarm outputs (Individually programmable)
  • 384 Fully programmable zones
  • 512 Fully programmable sounder groups together with 512 Input/Output groups
  • Event log (rolling, 2000 entries)
  • Compatible with GFE’s range of Analogue Addressable Devices
  • Backlit LCD display with 4 rows of 40 characters
  • PC Programming using Upload/Download GFE Connector Software
  • PC Graphics package ODYSSEY for alarm management and reporting (optional)
  • Multiple language support (menu selectable)
  • Integrated 16 zone LED fire zone indication

Specifications:
Technical SpecificationsJUNIOR V 4
Primarty Supply Voltage - In Put230+ 10 % -150 % V AC
Rimarty Supply Voltage - Out Put28.5 V DC nominal
Primarty Supply Current - Out Put2.4 A @ 28.5 V DC nominal (max)
Secondary Supply Voltage21.0 min. -27.2 Max V DC - BAT charger o/p 28 V DC
Secondary Supply Current Out put1.6 Amp Maximum @20 c
Internal Battery Capacity - Maximum2 x 12 v 7 Ah Sealed VRLA Lead Acid Batteries
Loop current drive275 m A / loop
Auxiliary Relay Outputs2 Fire (Com-NC- No) -1 fault (Com-NC ) non supervised
Conventional Sounder Circuits2-400 m A Max. current drive per circuit -Fully monitored.
Max. Humidity95% RH non Condensing
Operating Temperature0 c to 40 c
Weight2.0 kg -7 kg (inc.2x7AH 12 V bat.)
Dimensions272 (W) x 404 (H) x 107 (D)mm
Order CodeDescription
JNR_V4-1junior V4, 1 loop Expandable to 2 loopsm PUS 2.4 A
JNR_V4-2Junior V4, 2loops, PSU 2.4 A
JNR_V4- CARDjunior V4 loop Card Expansion form 1 to 2 loop
Yes! I am interested

Conventional Fire Alarm Panel

REQUEST CALLBACK

Conventional Fire Alarm Panel
Approx. Rs 4,200 / Piece(s)
Get Best Quote

The orion mini one & two zones Conventional Fire Alarm Panel, offers a creatively designed and aesthetically pleasing solution for smaller cost-conscious projects demanding simplicity of operation. The programmable features included in this panel are: programmable time delay and day/night mode. Operation is extremely inituitive, offering simple control and one-button disablement facilities, as well as the one man test mode which provides simple and efficient testing of the system.

Key Features:

  • Up to 32 conventional smoke and/or heat detectors per Zone
  • Active End of Line monitoring
  • Delay timer programmable On/ Off and Day/ Night Mode
  • One man test
  • 1 Supervised/ monitored sounder circuit
  • Fully EN 54 -2 and EN 54-4 compliant
  • Addressable Loop Interface card-GFE-ADLI (optional)

Technical Specifications:
Technical SpecificationsORION-MINI
Primary Supply Voltage- In230 +10% -15% V AC
Primary Supply Voltage/ Current- Out0.5 A @ 28.5 V DC nominal (max.)
Secondary Supply Voltage21.0 min. - 27.2 max.V DC - BAT charger o/p 28 V DC
Internal Battery Capacity - Maximum2 x 12 V x 1.2 Ah Sealed VRLA Lead Acid Batteries
Mains Fuse/ Battery Fuse1 A -250 V Slow Blow - 20 mm/ 1.0 Amp - Resettable
Zone Current - Quiescent/ Alarm4 mA/ 65 mA
Max. Cable Resistance/ Capacitance40 Ohms / 0.470 uF
End Of Line MonitoringActive EOL - Capacitor
Bs5839 Detector Removal CompliantYES provided diodes are fitted to detector base
Devices Per Zone32 Maximum - EN 54-2
Alarm Resistance Value270 - 1000 Ohms
Sounder Circuit Specification1 - 300 mA max. current drive per circuit - fully monitored
Alarm Voltage/ End Of Line Resistor27.5 V DC Nominal / 10 K Ohms - 1/4 Watt E.O.L.
Operating Temperature/ Max. Humidity-5ºC to 50ºC/ 95% RH Non-Condensing
Weight1.1 Kg - 2.3 Kg (inc. 2 x 1.2 AH 12 V bat.)
Dimensions256 (L) x 194 (W) x 86 (H) mm
Order CodeDescription
Orion Mini 1One Zone Conventional Fire Detection Control Panel- Low Profil
Orion Mini 2One Zone Conventional Fire Detection Control Panel- Low Profil
Yes! I am interested

Conventional Repeater Panel

REQUEST CALLBACK

Conventional Repeater Panel
Approx. Rs 4,200 / Piece
Get Best Quote

The orion mini-rep will provide remote control, system status display and monitoring functions. All fire, fault, test and disabled conditions are displayed. User is able to control all functions at access level’s 1 and 2. Compliant with en54-2. Display and control functions are replicated and shown in the same manner as on the orion fire detection panel. Access to level 2 is via a four digit code (same code as used on the orion conventional panel).

Features:

  • It includes as standard an RS232 interface

Other Details:


This unit is also compatible with all of GFE’s standard data loop interfaces, allowing the ORION MINI-REP panel to be interfaced to an ORION Conventional Panel using 4 different interfacing technologies:

  • RS232
  • RS485
  • Fiber Optics
  • TCP/IP ( Specific for Orion Conventional Systems)

Technical Specifications:
Technical SpecificationsOrion mini Rep
Supply Voltage28 v dc nominal derived from Orion Aux. Supply o/p
Supply Current40 m A
Connectionssupply, -Supply, TX and RX
Repeater NetworkRS 231, rs 485 , fo or TCP/ IP -1 Display & Control 3 Display Only
Max. Humidity95% RH Non - Condensing
Operating Temperature0 c to 40 c
Weight1.4kg
Dimensions256 (L) x 194 (W) x 75(H) mm
Order codeDescription
Orion Mini -RepConventionl Mini - pepeater Panel includes 1 x Rs 232 Interface
Yes! I am interested

 
X


Call Us:  +91-8048412669
Nrs Solutions A Co.
Sujatha Rajkumar (Head - Business Development)
No. 97/ A, 1st Stage, 6th Phase, Mahaganapathi Nagar, West Of Chord Road Industrial Town, Rajaji Nagar, Rajaji Nagar, Industrial Town,
Bengaluru - 560044, Karnataka, India
Contact via E-mail
Contact via SMS



Home  |   Profile   |  Our Gallery  |  Site Map  |   Contact Us   |   Mobile Site

© Nrs Solutions A Co.. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Nrs Solutions A Co.